Sign In | Join Free | My burrillandco.com
Home > AC High Voltage Test Equipment >

Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System

Sansion Power Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System from wholesalers
     
    Buy cheap Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System from wholesalers
    • Buy cheap Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System from wholesalers
    • Buy cheap Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System from wholesalers
    • Buy cheap Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System from wholesalers

    Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System

    Ask Lasest Price
    Model Number : SXGTU
    Brand Name : Sansion Power
    Delivery Time : 30 working days
    Payment Terms : L/C,T/T
    Certification : CE/SGS/EMS/ISO 9001
    • Product Details
    • Company Profile

    Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System

    Product Description

    The Complete GIS Testing Solution is positioned as a comprehensive platform for customers who need more than a single high-voltage test instrument.

    It combines GIS high-voltage withstand testing, partial discharge measurement and insulation diagnostics into a configurable testing solution for GIS manufacturers, utilities, laboratories and commissioning companies.

    The concept follows the current direction of GIS testing, where withstand testing and PD measurement are increasingly considered complementary rather than completely independent tests.

    Complete Testing Functions
    High Voltage Tests
    • AC withstand voltage test
    • Power-frequency withstand test
    • Variable-frequency AC test
    • Resonance high-voltage test
    • GIS insulation test
    Partial Discharge Tests
    • Partial discharge detection
    • PDIV measurement
    • PDEV measurement
    • Apparent charge measurement
    • PRPD analysis
    • UHF PD detection
    • Noise analysis
    • PD trend analysis
    Project Applications
    • GIS factory acceptance testing
    • GIS commissioning
    • GIS installation testing
    • GIS preventive maintenance
    • GIL testing
    • High-voltage laboratory testing
    • Research and development
    • Insulation diagnostic testing
    Why Choose a Complete GIS Test Solution?

    More than a withstand test

    The customer receives information about both dielectric withstand capability and PD activity.

    More efficient testing workflow

    The high-voltage source, measurement system and control system can be designed as one integrated solution.

    Flexible for different GIS projects

    Voltage level, test capacity, PD measurement method and control architecture can be customized.

    Suitable for international projects

    The system can be engineered according to the applicable project standards and customer specifications.

    FAQ
    What standards are commonly associated with GIS high-voltage and PD testing?

    Depending on the test being performed, customers may encounter standards such as IEC 62271-203, IEC 60060-1 and IEC 60270. The exact standard and test procedure should be confirmed according to the project specification and GIS application.

    What is the difference between IEC 60270 PD measurement and UHF GIS PD detection?

    IEC 60270 is associated with conventional apparent-charge measurement using a suitable measuring circuit, while UHF detection uses high-frequency electromagnetic signals generated by PD inside GIS. The two approaches have different measurement principles and application characteristics.

    Can one system support both methods?

    A customized GIS testing platform can be designed to support multiple PD measurement methods where required.

    How do I choose the right GIS test system?

    The most important information includes:

    • GIS rated voltage
    • Required test voltage
    • GIS capacitance
    • Test frequency
    • Required test current
    • PD measurement method
    • Required PD sensitivity
    • GIS configuration
    • Indoor or outdoor application
    • Factory or field testing
    • Applicable standards
    Can the system be customized for 110kV, 220kV, 500kV or higher GIS?

    Yes. High-voltage GIS testing systems are normally engineered according to the customer's actual GIS parameters rather than selected only by voltage class. For example, commercially available systems cover GIS testing at different voltage levels, while higher-voltage applications require corresponding changes to the test circuit, insulation design, capacity and site configuration.

    Quality Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sansion Power Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category: